Heat balance in hydraulic systems

The power loss in hydraulic systems results in an inflowing heat flow W z, which partly fills the heat capacity C of the oil and the metal parts surrounding it (pipes, cylinders, motors):

b5a8b27c93b5140416adaa6c636e58b10828f59c

Another part is radiated to the surrounding environment:

a9fd5ddd3199659f90dc8f9cf926df2cbe149cda

The oil container is primarily involved in this. Depending on the ventilation of the surface A, k = 5.8–11.6 W/m2K can be used if the temperature difference is at least 25°C.

This creates a heat balance.

b29f89ad23bd6068a67ac1b6fe25e0551b961d7a

If the stationary temperature reach is beneath the operating temperature T B, no further measures are necessary (Figure W 1, curve I). The same applies to the case that T B only reaches t B after the operating time given a largely rising curve (II). However, if this happens earlier, an oil cooler must be used (III).

5701f37619f6141839a7b2bca54ce021339497bc

Figure W 1: Possible change in temperature in the tank